Conditions of Use: |
Marine, Land Use |
---|---|
Usage: | Common Units |
Output Type: | DC |
Still deciding? Get samples of US$ 30/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Sensing Input | 160 to 265 Vac / 300 to 550 Vac 50/60 Hz |
Power Input | Voltage 90 to 270 Vac 1 phase, 50/60 Hz |
Output Voltage | Voltage Max. 63 Vdc @ 240 Vac input |
Output Current | Continuous 4A Intermittent 7A for 60 seconds |
Over Excitation Protection | Field volts shut down after a time delay if exciter field volts exceed 100 +/-5 Vdc |
Under Frequency Protection | 50 Hz system presets knee point at 45 Hz 60 Hz system presets knee point at 55 Hz |
Voltage Regulation | Less than +/-1% (with 4% engine governing) |
External Volts Adjustment | +/-15% with 1K ohm 1 watt trimmer |
Voltage Build-up | Residual volts at AVR terminal > 5 Vac |
EMI Suppression | Internal electromagnetic interference filtering |
Excitation Winding Resistance | Resistance Min. 15 ohms Max. 100 ohms |